Instinct sensor, made by Abbott, for MiniMed 780G
Control IQ with Dexcom

Summary

This is a CGM sensor made by Abbott, exclusively designed for MiniMed 780G system. It will work with MiniMed 780G and related systems. Wear time is up to 15 days, and warm-up is ~1 hour. Fingersticks are not required in closed-loop mode.

FDA approved for ages 7+ for use on the upper arm (back of upper arm)

MARD of ~8.5%

This system combines the Tandem t:slim x2 with the Dexcom G6 or G7 continuous glucose monitor (CGM) to automatically adjust insulin delivery in response to glucose trends. It's easy to use and allows bolus dosing directly from a compatible iOS or Android smartphone. 

Components

Sensor

Sensor

Sensor uses a thin, flexible filament beneath the skin to continuously measure glucose every 5 minutes. Simple, one-step applicator makes insertion fast and easy.

Infusion Set

Infusion Set

An infusion set contains the thin plastic tubing that delivers insulin from the pump to the body.

Controller

Controller

t:slim pump receives CGM readings to automatically adjust basal insulin delivery via an infusion set. Compatible smartphone can be used to view and administer boluses via the t:connect app.

Sensor

Sensor

Automatic applicator inserts sensor just under the surface of the skin and can be applied to many places on the body.

Pump

Pump

Touch screen pump connects tubing to a small patch called an infusion set that attaches to the body.

Device Details

Overview

Compact all-in-one sensor sensor, made by Abbott, exclusively designed for MiniMed 780G system.

The system automatically adjusts insulin levels from the Tandem t:slim X2 pump based on the Dexcom G6 or G7 readings for more time in range. 

Affordability and Access

$$$$
Coverage will depend on insurance policies and Medtronic’s rollout plan

$$$$
Widely covered for insulin-dependent type 1 and 2. Supplies for Pump and Sensor provided by DME suppliers. Price range; $5-$6,995 to start and $0-$200/month.

Data Monitoring Options

Yes
Data streams directly to the pump; users and clinicians can view trends and logs via Medtronic’s platforms.

Yes
The t:connect mobile app for the t:slim X2 pump wirelessly uploads pump and CGM data to the cloud-based t:connect web application.

Data View Options

Yes
Data view directly on your connected pump or smart device. 

Yes
Data can be viewed directly on the pump screen or on the t:connect mobile app (available for both iOS and Android devices).

Duration and Storage

15 Days
Sensors last up to 15 days and need about 1 hour to warm up. They work between 50ºF – 113ºF and should be stored between 36ºF – 82ºF. They are usually shipped in 1–3 month supplies, which is about 2–6 sensors at a time.

3-day pump 10-day sensor
Sensors last 10 days and transmitters last 90 and work at 50ºF – 108ºF. Pump can be used for up to 72 hrs, battery life lasts five days with the use of CGM, and work between 40°F - 99°F. 

*CGM transmitter is only required for the Dexcom G6 model. 

Vision / Auditory / Dexterity

YES text to speech
YES vibration alerts
Multiple sound sources
SOME dexterity needed

NO text to speech
YES 
vibration alerts
A LOT
of dexterity needed

Patient Considerations

Active Lifestyle

Long wear & water resistant. Longer wear reduces change burden; sensor design aims for robustness with movement. Water-resistant up to 3 feet (1 m) for 30 minutes (same standard as FreeStyle Libre family).

Exercise Activity. Can manually increase target range to 140-160 mg/dl. Insulin decreases when Control IQ predicts CGM ≤140 mg/dl and increases when ≥ 160 mg/dl within 30 minutes. Autocorrections will still occur. Pump is not waterproof. CGM is waterproof. 

Avoiding Highs and Lows

Continuous closed-loop insulin adjustment helps maintain tighter control.

Auto basal and bolus insulin. Responds to CGM data by increasing or decreasing basal insulin delivery to prevent highs and lows and maintain a target blood glucose of 110 mg/dl. Auto-bolus is available once per hour to correct blood sugar above 180 mg/dl.

Comfort

Small & Discreet. Very small, discreet form factor, and minimal bulk.

Low profile. Low profile/low maintenance sensor. Small tubed pump with the most infusion sets to pick from.

Easy Insulin Dosing

MiniMed 780G closed-loop algorithm: adjusts basal and delivers automatic correction boluses using sensor data. Longer wear (15 days) means fewer interruptions in automated dosing. In manual mode, it still requires fingerstick confirmation before dosing from sensor values.

Automatically adjusts dosing. Sensor integration allows for the pump to automatically adjust insulin doses. More customizable dosing than pens or syringes. Basal in 0.001 increments, bolus in 0.01 increments. Extended bolus available.

Easy to Use

Longer sensor life and shorter warm-up (~1 hour) help with convenience.

Modern & flexible. Rechargeable and touchscreen pump. Sensor integrated with multiple devices in case you change up what you're using. 

Fewer Fingersticks

Factory-calibrated sensor. Finger sticks needed for backup only.

Factory-calibrated sensor. Fingersticks needed for backup only.

Privacy

Small & Customizable. Extremely small (about the size of two stacked pennies), designed to be less noticeable under clothing. Upper arm site only; discreet but still visible with sleeveless clothing. Alerts can be customized on the connected pump for quieter use.

Discreet. Ability to check blood sugar on phone or watch. Ability to bolus on a compatible smartphone. Pump has tubing but can be clipped to clothing or placed in a pocket to be discreet when needed. Dexcom's built-in hypoglycemia safety alarm alerts users when glucose is below 55 mg/dl and is always on.