Instinct sensor, made by Abbott, for MiniMed 780G
NovoPen 6/NovoPen Echo

Summary

This is a CGM sensor made by Abbott, exclusively designed for MiniMed 780G system. It will work with MiniMed 780G and related systems. Wear time is up to 15 days, and warm-up is ~1 hour. Fingersticks are not required in closed-loop mode.

FDA approved for ages 7+ for use on the upper arm (back of upper arm)

MARD of ~8.5%

NovoPen 6 & NovoPen Echo Plus provides the smart addition of a personal injection log. Both pens are compatible with Novo Nordisk insulins in Penfill 3 ml cartridges and work with NovoFine single-use disposable needles. You can transfer your insulin dosing information from your smart pen to your device using the app. 

Components

Sensor

Sensor

Sensor uses a thin, flexible filament beneath the skin to continuously measure glucose every 5 minutes. Simple, one-step applicator makes insertion fast and easy.

Receiver

Receiver

Smart pen and sensor readings displays dosage information directly on smart mobile device.

Controller

Controller

Smart pen records daily injections and sends them to the compatible app by tapping the device with a compatible smartphone.

Sensor

Sensor

Sensor uses a thin, flexible filament inserted just under the skin to measure glucose levels every 5 minutes. Push-button applicator allows sensor to be placed on the body in one step.

Device Details

Overview

Compact all-in-one sensor sensor, made by Abbott, exclusively designed for MiniMed 780G system.

Discreet and modern option for people using multiple daily injections.

Affordability and Access

$$$$
Coverage will depend on insurance policies and Medtronic’s rollout plan

$$$$
Sometimes covered. NovoPens are covered by some commercial insurance companies; typically, users pay $21 out-of-pocket copays for the eight-month device. Prices range from $0- $78. For those without any insurance coverage, a single pen price is $78.

Data Monitoring Options

Yes
Data streams directly to the pump; users and clinicians can view trends and logs via Medtronic’s platforms.

Yes
Hold the dose memory of the pen straight against the Near Field Communication (NFC) spot on your device. Wait while your injection details are automatically transferred to a compatible app on your device. Compatible with multiple data monitoring platforms, including Glooko, MySugr, and Dose Check

Data View Options

Yes
Data view directly on your connected pump or smart device. 

Yes
Dose-related data can be viewed on the NovoPen 6 & NovoPen Echo apps. 

Duration and Storage

15 Days
Sensors last up to 15 days and need about 1 hour to warm up. They work between 50ºF – 113ºF and should be stored between 36ºF – 82ºF. They are usually shipped in 1–3 month supplies, which is about 2–6 sensors at a time.

28-day pen (Compatible with 10-day or 14-day sensor)
Sensor lasts for 10-14 days depending on the brand, insulin pen lasts for up to 28 days. Pen has 800-injection dose memory and a five-year battery life. Sensor works between 50ºF - 113ºF and pens can be kept at room temperature for up to 28 days. 

 

Vision / Auditory / Dexterity

YES text to speech
YES vibration alerts
Multiple sound sources
SOME dexterity needed

NO text to speech
NO vibration alerts
A LOT of dexterity needed

Patient Considerations

Active Lifestyle

Long wear & water resistant. Longer wear reduces change burden; sensor design aims for robustness with movement. Water-resistant up to 3 feet (1 m) for 30 minutes (same standard as FreeStyle Libre family).

Light on body. Pens are easy to use and do not remain attached to the body, senor is light on the body.

Avoiding Highs and Lows

Continuous closed-loop insulin adjustment helps maintain tighter control.

Limited customizability. System integrates the Dexcom G6/G7 or Libre CGM for high or low alerts but requires manual dose adjustment and limits the ability to adjust insulin levels throughout the day. 

Comfort

Small & Discreet. Very small, discreet form factor, and minimal bulk.

Many components. Have to carry pens and pen needles. CGM is attached to the body.

Easy Insulin Dosing

MiniMed 780G closed-loop algorithm: adjusts basal and delivers automatic correction boluses using sensor data. Longer wear (15 days) means fewer interruptions in automated dosing. In manual mode, it still requires fingerstick confirmation before dosing from sensor values.

NovoPen 6The maximum dose is 60 units, and doses increase in 1-unit increments. NovoPen Echo PlusThe maximum dose is 30 units, and doses increase in 0.5-unit increments

Easy to Use

Longer sensor life and shorter warm-up (~1 hour) help with convenience.

Simple design. Replaces regular insulin pen. No additional devices to add on. 

Fewer Fingersticks

Factory-calibrated sensor. Finger sticks needed for backup only.

Factory-calibrated sensor. Finger sticks needed for backup only. 

Privacy

Small & Customizable. Extremely small (about the size of two stacked pennies), designed to be less noticeable under clothing. Upper arm site only; discreet but still visible with sleeveless clothing. Alerts can be customized on the connected pump for quieter use.

Hideable. Pens are portable but visible when in use. Frequent injections are unavoidable. View recommendations and data on a smartphone.