Tandem Mobi
Medtronic Simplera Sync

Summary

The Tandem Mobi is the smallest durable automated insulin delivery system available in the U.S. that can be fully controlled by a mobile device. The pump is equipped with an on-pump button for users to bolus insulin directly from the pump if they don’t want to do it from their phone. This system is combined with the Dexcom continuous glucose monitor (CGM) to automatically adjust insulin delivery in response to glucose trends. 

*Compatiblilty with Dexcom G7 now available 

This is a disposable, all-in-one CGM sensor integrated with Medtronic’s pump systems (e.g., MiniMed 780G). Typical wear time is 6 days, plus a 24-hour “grace period.” No routine fingersticks are required when the device is in closed-loop/SmartGuard mode.

FDA approved for ages 7+ on the back of the upper arm

MARD of ~9%

Components

Infusion Set

Infusion Set

An infusion set contains the thin plastic tubing that delivers insulin from the pump to the body.

Controller

Controller

Mobi pump receives CGM readings to automatically adjust basal insulin delivery via an infusion set. Compatible smartphone can be used to view and control insulin delivery.

Sensor

Sensor

Automatic applicator inserts sensor just under the surface of the skin and can be applied to many places on the body.

Pump

Pump

Small pump connects tubing to a 5 inch tubing patch called an infusion set that attaches to the body.

Sensor

Sensor

Sensor uses a thin, flexible filament beneath the skin to continuously measure glucose every 5 minutes. Simple, one-step applicator makes insertion fast and easy.

Device Details

Overview

Tandem Mobi is the smallest insulin delivery system to be fully controlled by a smartphone.

Disposable, all-in-one CGM sensor integrated with Medtronic’s pump systems

Affordability and Access

$$$$
Pump coverage is not yet available. Sensor is widely covered and provided by DME and/or Pharmacy. Sensor price range; $0-$500/month.

$$$$
Coverage depends on region and insurance; supplied via DME or specialty pharmacy.

Data Monitoring Options

Yes
The t:connect mobile app for the t:slim X2 pump wirelessly uploads pump and CGM data to the cloud-based t:connect web application.

Yes
Data streams directly to the pump; users and clinicians can view trends and logs via Medtronic’s platforms.

Data View Options

Yes
Data can be viewed directly on the pump screen or on the t:connect mobile app (available for both iOS and Android devices).

Yes
Data view directly on your connected pump or smart device. 

Duration and Storage

3-day pump 10-day sensor
Sensors last 10 days and transmitters last 90 and work at 50ºF – 108ºF. Pump can be used for up to 72 hrs, battery life lasts five days with the use of CGM, and work between 40°F - 99°F. Pump supports wireless charging.

6 Days
Sensors last 6 days, with a 24-hour grace period, and need about 2 hours to warm up. They work between 41°F – 104°F and should be stored between 36°F – 86°F. They are usually shipped in 1–3 month supplies, which is about 5–15 sensors at a time.

Vision / Auditory / Dexterity

NO text to speech
YES 
vibration alerts
A LOT 
of dexterity needed

YES text to speech
YES vibration alerts
Multiple sound sources
Moderate dexterity needed

Patient Considerations

Active Lifestyle

Waterproof. The pump and CGM are waterproof and can be worn for most exercises.

Compact and integrated. Reducing bulk; compatibility with daily activities depends on the adhesive and body movement. Water-resistant up to 8 feet (2.4 m) for 30 minutes.

Avoiding Highs and Lows

Auto basal and bolus insulin. Responds to CGM data by increasing or decreasing basal insulin delivery to prevent highs and lows and maintain a set blood glucose target. 

SmartGuard closed-loop. Pump adjustments use sensor data continuously to reduce highs and lows.

Comfort

Shorter tubing option. A shorter 5-inch tubing option for comfort on body. 

Low profile. No overtape needed and one-hand insertion.

Easy Insulin Dosing

Automatically adjusts dosing. Sensor integration allows the pump to automatically adjust insulin doses. More customizable dosing than pens or syringes. Manual bolus button is available for quick dosing without a phone. 

SmartGuard technology. When paired with the MiniMed 780G, it automatically adjusts basal and gives correction boluses based on sensor readings. In manual mode, glucose values can guide dosing decisions, but fingersticks are required for confirmation.

Easy to Use

Easy Dosing. Full control from a smartphone, with the option to manually bolus if needed.

All-in-one. Eliminates the need for a separate transmitter, simplifying sensor changes (although more frequent due to the 6-day wear).

Fewer Fingersticks

Factory-calibrated sensor. Fingersticks needed for backup only.

Calibration is optional. Perfect if you like having that choice.

Privacy

Discreet. Ability to check blood sugar on phone or watch. Ability to bolus on a compatible smartphone. Pump has tubing but can be clipped to clothing or attached to local area with an armband or adhesive sleeve to be discreet when needed. Dexcom's built-in hypoglycemia safety alarm alerts users when glucose is below 55 mg/dl and is always on.

Small and integrated, but visible on the back of the arm. No separate transmitter reduces the number of visible parts. Alerts and alarms can be adjusted for discretion.