twiist
Syringe and Vial
Summary
The twiist AID system was cleared by the FDA for use with CGMs that have received FDA designation as integrated continuous glucose monitors (iCGMs). As the twiist AID system gets closer to commercial availability, Sequel Med Tech will publicize the list of compatible CGM
*Recently FDA approved for people with type 1 diabetes ages 6 and up.
Traditional syringe and needle. The most affordable insulin delivery option.
Components
Infusion Set
An infusion set contains the thin plastic tubing that delivers insulin from the pump to the body.
Controller
Pump is controlled by the twiist app on an iPhone. Data from both the pump and CGM are viewable on the twiist app Home Screen.
Pump
Pump can be worn with a pump clip, adhesive patch or in a pocket.
Needles
Classic syringes with plunger used to fill insulin for injection
Long-acting insulin
Basal (long-acting) insulin vial for steady release of insulin that helps control blood sugar between meals, and overnight.
Rapid-acting insulin
Bolus (fast-acting) insulin vial for meal time or high blood sugar correction.
Device Details
Overview
This system automatically adjusts insulin delivery according to continuous glucose monitor (CGM) readings and predicted blood sugar levels. It is the first FDA-approved AID system with Apple Watch compatibility.
Nothing on the body when not in use but very visible when dosing.
Affordability and Access
$$$$
No insurance coverage data. Anticipated to be provided through Pharmacy.
$$$$
Syringes are available worldwide in pharmacies or DME without prescription. Price Range: $0-$300/month depending on insurance coverage.
Data Monitoring Options
Yes
Compatible with Tidepool - a web-based diabetes data management system.
No Options
Data View Options
Yes
Data is stored and can be viewed directly from the twiist app on the mobile device (iPhone), and can be linked to an Apple Watch for viewing data as well.
No Options
Duration and Storage
3-day pump 10-day sensor
Sensors last 10 days, and transmitters last 90 and work at 50ºF – 108ºF. The reservoir holds 300 units and is disposable, and the pump can be used for up to 3 years.
28 Days
Open vials can be stored at room temperature (not above 80º F) for up to 28 days. Unopened vials should be stored in the refrigerator (36ºF - 86ºF.)
Vision / Auditory / Dexterity
YES text to speech
YES vibration alerts
A LOT of dexterity needed
NO text to speech
NO vibration alerts
A LOT dexterity for insertion
Patient Considerations
Active Lifestyle
Waterproof. The pump, when connected to the cassette, has a rating of IP28, indicating protection from continuous immersion in water. The pump can tolerate immersion to depths of up to 12 feet (3.7 m) for 1 hour.
Limited Adjustability. No way to adjust long-acting insulin for higher activity on the fly.
Avoiding Highs and Lows
Automatically adjusts insulin delivery. Increases or decreases insulin delivery to meet glucose targets. Insulin delivery settings can be aggressive or conservative.
Limited customizability. Requires a high level of engagement and effort to avoid highs and lows but can be paired with a CGM for improved blood sugar control.
Comfort
Low-profile. Low profile with an adhesive design that prevents the pump from catching on other objects.
Many components. Must carry insulin vials and large syringes but nothing attached to the body.
Easy Insulin Dosing
Customizable. Can bolus from phone, smartwatch, or directly from the device without needing to be attached to your phone. The device also directly measures the volume (amount) and flow (speed) of insulin delivered with every micro-dose
Requires attention. You have to do the math to figure out your dose. Unable to adjust basal in real-time.
Easy to Use
Watch compatible. The twiist AID system is the first FDA-approved AID system that can be directly controlled from an Apple Watch.
Many steps. Requires effort to figure out doses and deliver insulin every single time you need it.
Fewer Fingersticks
Factory-calibrated sensor. Fingersticks needed for backup only.
Frequent finger-sticks are required.
Privacy
Discreet. The pump is in two pieces - the top (algorithm and battery) and the bottom (insulin chamber and AVS technology)
Hideable. Vials and syringes can be hidden when not in use but very visible when in use. Frequent injections are unavoidable.