Medtronic Simplera Sync
Omnipod GO Patch

Summary

This is a disposable, all-in-one CGM sensor integrated with Medtronic’s pump systems (e.g., MiniMed 780G). Typical wear time is 6 days, plus a 24-hour “grace period.” No routine fingersticks are required when the device is in closed-loop/SmartGuard mode.

FDA approved for ages 7+ on the back of the upper arm

MARD of ~9%

The Omnipod GO is a patch pump that provides a fixed rate of continuous rapid-acting insulin in seven rates ranging from 10 to 40 units per day for up to 72 hours. This device is a standalone tubeless, waterproof pod that provides a convenient alternative to traditional insulin delivery methods.

FDA-approved for people 18 years of age and older with type 2 diabetes who need long-acting insulin injections.

*Omnipod GO is expected to be commercially available in the United States in 2024

Components

Sensor

Sensor

Sensor uses a thin, flexible filament beneath the skin to continuously measure glucose every 5 minutes. Simple, one-step applicator makes insertion fast and easy.

Patch

Patch

Pods come with reservoirs and directions for application. They can be applied anywhere on the body that is comfortable.

Reservoir

Reservoir

Fill reservoir is enclosed with the Pod and used to manually fill the Pod with insulin.

Device Details

Overview

Disposable, all-in-one CGM sensor integrated with Medtronic’s pump systems

Convenient, waterproof, and simple to use.

Affordability and Access

$$$$
Coverage depends on region and insurance; supplied via DME or specialty pharmacy.

$$$$
Widely covered for insulin-dependent 2. Supplies provided by DME or pharmacy. Price range; $33-$46/unit.

Data Monitoring Options

Yes
Data streams directly to the pump; users and clinicians can view trends and logs via Medtronic’s platforms.

No Options

Data View Options

Yes
Data view directly on your connected pump or smart device. 

No Options

Duration and Storage

6 Days
Sensors last 6 days, with a 24-hour grace period, and need about 2 hours to warm up. They work between 41°F – 104°F and should be stored between 36°F – 86°F. They are usually shipped in 1–3 month supplies, which is about 5–15 sensors at a time.

72-Hours 
Patch can be worn for up to 72 hours and works in most temperatures (not for use in hot tubs, saunas, or freezing conditions). Does not require batteries or recharging.

Vision / Auditory / Dexterity

YES text to speech
YES vibration alerts
Multiple sound sources
Moderate dexterity needed

NO text to speech
NO vibration alerts
A LOT of dexterity needed

Patient Considerations

Active Lifestyle

Compact and integrated. Reducing bulk; compatibility with daily activities depends on the adhesive and body movement. Water-resistant up to 8 feet (2.4 m) for 30 minutes.

Tubeless and waterproof pod. No way to adjust long-acting insulin for higher activity on the fly, but the device is tubeless and waterproof. 

Avoiding Highs and Lows

SmartGuard closed-loop. Pump adjustments use sensor data continuously to reduce highs and lows.

Limited customizability. System requires manual dose adjustment and limits the ability to adjust insulin levels throughout the day. 

Comfort

Low profile. No overtape needed and one-hand insertion.

Free of tubing. Patches do not have tubing.

Easy Insulin Dosing

SmartGuard technology. When paired with the MiniMed 780G, it automatically adjusts basal and gives correction boluses based on sensor readings. In manual mode, glucose values can guide dosing decisions, but fingersticks are required for confirmation.

Modifiable. The pod is available in seven different pre-programmed daily rates, ranging between ten and 40 units a day.

Easy to Use

All-in-one. Eliminates the need for a separate transmitter, simplifying sensor changes (although more frequent due to the 6-day wear).

Simple with few steps. Patch is replaced every 72-hours with a fixed rate of continuous rapid-acting insulin. 

Fewer Fingersticks

Calibration is optional. Perfect if you like having that choice.

Frequent finger-sticks are required.

Privacy

Small and integrated, but visible on the back of the arm. No separate transmitter reduces the number of visible parts. Alerts and alarms can be adjusted for discretion.

Hideable. Bulkier patch pump, but not as noticeable as injections.